Accessible Dining Tables or Counters require a clear floor space of 30 inches by 48 inches minimum with 19 inches minimum of that space under the table for wheelchair access.
Top of table measured to top of floor is 30 inches maximum.
Bottom edge of table measured from top of floor is 27 inches minimum.
30 inches by 48 inches clear floor space cannot have anything on the floor.
30 inches by 48 inches clear floor space cannot have any table supports.
Accessible dining or drinking bar/counter needs to meet the above requirements and must have a bar/counter surface a minimum of 60 inches in width.
A MINIMUM of 5 percent of the seating spaces and standing spaces at the dining/bar/counter surfaces shall be accessible.
Accessible seating is required to be dispersed throughout with accessible seating in each type of seating.
Hilliard Architects is a small technical architecture firm specializing in laboratory and healthcare renovations and access compliance (ADA).